Used for fastening various single-ply roofing membranes including TPO, PVC, SBS, and KEE, installed over common insulation layers such as XPS, PIR, or EPS. A recommended membrane overlap width of 150 mm should be maintained.
Specifically designed for membranes over 2.4 meters in width, the 60 mm diameter provides a larger fixing area, enhancing pressure distribution and wind uplift resistance
The toothed base design firmly grips the membrane's reinforcement layer, significantly improving pull-out strength and wind uplift performance to ensure system stability
The circular configuration ensures even stress distribution and facilitates easy installation, delivering an efficient and reliable fastening solution for wide membrane systems
Item | Detail |
Gasket Dimensions | Φ 60mm |
Gasket Thickness | 0.8/1 mm |
Hole Diameter | 6.5mm |
Gasket Material | 150 g Aluzinc Steel Sheet |
Design Load | 800N |
Pull-out Strength | ≥2000N |
Compliance Standard | JG/T 576-2021 |
Application Scenario | Waterproofing membranes with a width ≥ 2.4 m |